2012 Acura RLFACTORY OEM SERVICE PROCEDURE

Symptom Troubleshooting Index

SYMPTOM TROUBLESHOOTING INDEX

Symptom Diagnostic procedure Also check for
Charging system indicator does not come on with the ignition switch in ON (II) Troubleshoot the charging system indicator circuit (see CHARGING SYSTEM INDICATOR CIRCUIT TROUBLESHOOTING ).  
Charging system indicator stays on
  1. Check for a broken drive belt (see DRIVE BELT INSPECTION ).
  2. Troubleshoot the charging system indicator circuit (see CHARGING SYSTEM INDICATOR CIRCUIT TROUBLESHOOTING ).
  3. Check the drive belt auto-tensioner (see DRIVE BELT REPLACEMENT ).
  4. Check for PGM-FI DTCs (see GENERAL TROUBLESHOOTING INFORMATION ).
 
Battery discharged
  1. Check for a poor connection at the battery terminal.
  2. Test the battery (see BATTERY TEST ).
  3. Troubleshoot the alternator and regulator circuit (see ALTERNATOR AND REGULATOR CIRCUIT TROUBLESHOOTING ).
  4. Check for a broken drive belt (see DRIVE BELT INSPECTION ).
  5. Check the drive belt auto-tensioner (see DRIVE BELT REPLACEMENT ).
  6. Check for excessive parasitic current draw with the ignition switch in LOCK (0), and the key removed. The multiplex control units may take up to 10 minutes to turn off (sleep mode) for some models.
 
Battery overcharged
  1. Test the battery (see BATTERY TEST ).
  2. Troubleshoot the alternator and regulator circuit (see ALTERNATOR AND REGULATOR CIRCUIT TROUBLESHOOTING ).
 
Low or dead battery Battery system troubleshooting (see BATTERY TEST )  
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.