2012 Acura MDXFACTORY OEM SERVICE PROCEDURE

Rear Power Window Motor Test

  1. Remove the door panel (see FRONT DOOR PANEL REMOVAL/INSTALLATION ), and disconnect the rear power window switch 14P connector (A).
    Fig 1: Identifying 14P Connector On Door Panel
    G08055422Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Test the power window motor in each direction by connecting battery power and ground according to the table. When the motor stops running, disconnect one lead immediately.
    Fig 2: Identifying Battery Power And Ground Reference Table
    G08055423Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. If the motor does not run or fails to run smoothly, go to step 4.
  4. Disconnect the 6P connector (A) from the rear power window motor (B).
    Fig 3: Identifying 6P Connector And Rear Power Window
    G08055424Courtesy of AMERICAN HONDA MOTOR CO., INC.

    The illustration shows the right rear door, the left rear door is similarly configured.

  5. Check for continuity between rear power window motor 6P connector terminals No. 1 and No. 2 and rear power window switch 14P connector terminals No. 1 and No. 7 respectively. There should be continuity.
    • If there is no continuity, repair an open in the wire.
    • If there is continuity, replace the power window motor.
    Fig 4: Checking Continuity Between Rear Power Window Motor 6P Connector And Rear Power Window Switch 14P Connector (Left)
    G08055425Courtesy of AMERICAN HONDA MOTOR CO., INC.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.