2009 Acura CSX Base, StandardFACTORY OEM SERVICE PROCEDURE
Passenger's Mode Control Motor Test
WARNING: This page is about a different car, the 2011 Acura TL, 2010 Acura TL, and 2009 Acura TL. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Before testing the motor, check for HVAC DTCs (see
GENERAL TROUBLESHOOTING INFORMATIONΒ )
- Disconnect the 7P connector from the passenger's mode control motorNOTE: Incorrectly applying power and ground to the mode control motor will damage it Follow the instructions carefully
- Connect battery power to terminal No 1 of the passenger's mode control motor, and ground terminal No 2, the passenger's mode control motor should run, and stop at Vent If it doesn't, reverse the connections, the passenger's mode control motor should run, and stop at Defrost When the passenger's mode control motor stops running, disconnect battery power immediately
- If the passenger's mode control motor did not run in step 2, remove it, then check the mode control linkage and door for smooth movement
- If the linkage and door move smoothly, replace the passenger's mode control motor (see PASSENGER'S MODE CONTROL MOTOR REPLACEMENTΒ )
- If the linkage or door sticks or binds, repair them as needed
- If the passenger's mode control motor runs smoothly, go to step 4
- Use a digital multimeter with an output of 1 mA or less at the 20 kΞ© range Operate the passenger's mode control motor as in step 2, and check for continuity between terminals No 3, 4, 5, and 6 and terminal No 7 individually There should be continuity for a moment at each terminal as the motor moves through its travel
- If there is no continuity for a moment at each terminal, replace the passenger's mode control motor (see PASSENGER'S MODE CONTROL MOTOR REPLACEMENTΒ )
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.