2008 Acura TL V6-3.2LFACTORY OEM SERVICE PROCEDURE

Ignition System: Testing and Inspection

Ignition Coil Relay Circuit Troubleshooting

1. Check the No. 2 (15 A) fuse in the under-dash fuse/relay box.

Is the fuse OK?

YES - Reinstall the fuse, then go to step 2.

NO - Replace the fuse. If the fuse continues to blow, locate and repair the short in the circuit between the under-dash fuse/relay box and the ignition coils.

2. Remove the ignition coil relay from the under-dash fuse/relay box, and test it.

Is the relay OK?

YES - Go to step 3.

NO - Replace the ignition coil relay.

Factory service manual diagram



3. Measure the voltage between ignition coil relay 4P socket terminal No. 1 and body ground, then terminal No. 4 and body ground.

Is there battery voltage?

YES - Go to step 4.

NO - Replace the under-dash fuse/relay box.

Factory service manual diagram



4. Check for continuity between ignition coil relay 4P socket terminal No. 2 and the each ignition coil 3P connector terminal No. 3.

Is there continuity?

YES - Go to step 5.

NO - Repair open in the wire between ignition coil relay 4P socket terminal No. 2 and each ignition coil 3P connector terminal No. 3.

Factory service manual diagram



5. Check for continuity between each ignition coil 3P connector terminal No. 2 and the body ground.

Is there continuity?

YES - Go to step 6.

NO - Repair open in the wire between ignition coil 3P connector terminal No. 2 and the body ground.

6. Connect the Honda Diagnostic System (HDS) to the data link connector (DLC).
7. Turn the ignition switch ON (II).
8. Make sure the HDS communicates with the vehicle and the engine control module (ECM)/powertrain control module (PCM). If it doesn't communicate, troubleshoot the DLC circuit.
9. Jump the SCS line with the HDS, then turn the ignition switch OFF.

NOTE: This step must be done to protect the ECM/PCM from damage.

10. Disconnect ECM/PCM connector E (31P).

Factory service manual diagram



11. Check for continuity between ignition coil relay 4P socket terminal No. 3 and body ground.

Is there continuity?

YES - Repair short in the wire between ignition coil relay 4P socket terminal No. 3 and the ECM/PCM (E5).

NO - Go to step 12.

Factory service manual diagram



12. Check for continuity between ignition coil relay 4P socket terminal No. 3 and ECM/PCM connector terminal E5.

Is there continuity?

YES - The system is OK at this time. Check for loose or poor connections at the ignition coil relay and the ECM/PCM (E5).

NO - Repair open in the wire between ignition coil relay 4P socket terminal No. 3 and the ECM/PCM (E5).
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.