2008 Acura RL V6-3.5LFACTORY OEM SERVICE PROCEDURE

Control Unit Input Test

Control Unit Input Test

NOTE: Before testing, troubleshoot the multiplex integrated control system first using B-CAN System Diagnosis Test Mode A.

1. Turn the ignition switch OFF.
2. Remove the driver's dashboard undercover, and the driver's dashboard lower cover.
3. Disconnect the connectors (A) from the keyless access control unit (B).

NOTE: All connector views are wire side of female terminals.

Factory service manual diagram





4. Inspect the connector and socket terminals to be sure they are all making good contact.
- If the terminals are bent, loose or corroded, repair them as necessary and recheck the system.
- If the terminals look OK, go to step 5.

5. With the connectors still disconnected, make these input tests at the connectors.
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, go to step 6.

Factory service manual diagram





6. Reconnect the connectors to the keyless access control unit, and make these input tests at the connectors.
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, the control unit must be faulty; replace it.

Factory service manual diagram



Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.