Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2004 Acura MDX BaseFACTORY OEM SERVICE PROCEDURE
Climate Control Unit Inputs and Outputs
WARNING: This page is about a different car, the 2009 Acura MDX, 2008 Acura MDX, and 2007 Acura MDX. However, it is still accessible from the selected car via links, so may be relevant.
CONNECTOR AΒ
CLIMATE CONTROL UNIT INPUTS AND OUTPUTS - CONNECTOR A
| Cavity | Wire color | Signal | |||
|---|---|---|---|---|---|
| 1 | WHT | BACKUP | INPUT | ||
| 2 | YEL | NAVIGATION UNIT (SI)(1) | INPUT | ||
| 3 | YEL | IG2 (Power) | INPUT | ||
| 4 | LT GRN | B-CAN | INPUT/OUTPUT | ||
| 5 | LT BLU | IN-CAR TEMPERATURE SENSOR | OUTPUT | ||
| 6 | GRY | COMMON POTENTIAL 5V | OUTPUT | ||
| 8 | RED | SENSOR COMMON GROUND | INPUT | ||
| 9 | BLU | FRONT BLOWER FEEDBACK | INPUT | ||
| 10 | RED | FRONT POWER TRANSISTOR CONTROL | OUTPUT | ||
| 11 | PUR | DRIVER'S AIR MIX POTENTIAL | INPUT | ||
| 12 | PNK | DRIVER'S AIR MIX HOT | OUTPUT | ||
| 13 | LT BLU | DRIVER'S AIR MIX COOL | OUTPUT | ||
| 14 | LT GRN | PASSENGER'S AIR MIX HOT | OUTPUT | ||
| 15 | YEL | PASSENGER'S AIR MIX COOL | OUTPUT | ||
| 16 | GRN | FRONT MODE DEF | OUTPUT | ||
| 17 | ORN | FRONT MODE VENT | OUTPUT | ||
| 18 | YEL | FRESH | OUTPUT | ||
| 19 | ORN | RECIRCULATE | OUTPUT | ||
| 21 | BLU | NAVIGATION UNIT(CLK)(1) | OUTPUT | ||
| 22 | RED | NAVIGATION UNIT (SO)(1) | OUTPUT | ||
| 23 | LT BLU | ILLUMK+) | INPUT | ||
| 24 | BRN | FRONT EVAPORATOR TEMPERATURE SENSOR | OUTPUT | ||
| 25 | PUR | ACC | INPUT | ||
| 26 | LT GRN | A/C PRESSURE SENSOR | OUTPUT | ||
| 27 | YEL | HUMIDITY SENSOR | OUTPUT | ||
| 28 | PNK | OUTSIDE AIR TEMPERATURE SENSOR | OUTPUT | ||
| 29 | PUR | SUNLIGHT SENSOR | OUTPUT | ||
| 30 | BLU | PASSENGER'S AIR MIX POTENTIAL | INPUT | ||
| 31 | WHT | FRONT MODE CONTROL MODE 1 | OUTPUT | ||
| 32 | LT GRN | FRONT MODE CONTROL MODE 2 | OUTPUT | ||
| 33 | PUR | FRONT MODE CONTROL MODE 3 | OUTPUT | ||
| 34 | BLU | FRONT MODE CONTROL MODE 4 | OUTPUT | ||
| 35 | WHT | RECIRCULATION CONTROL MODE 1 | OUTPUT | ||
| 36 | BLK | RECIRCULATION CONTROL MODE 2 | OUTPUT | ||
| 37 | BLK | GROUND (G506) | OUTPUT | ||
| 38 | GRN | RECIRCULATION CONTROL MODE 3 | OUTPUT | ||
|
|||||
CONNECTOR BΒ
CLIMATE CONTROL UNIT INPUTS AND OUTPUTS - CONNECTOR B
| Cavity | Wire color | Signal | |
|---|---|---|---|
| 1 | GRN | REAR AIR MIX COOL | OUTPUT |
| 2 | PNK | REAR AIR MIX HOT | OUTPUT |
| 3 | YEL | REAR MODE HEAT | INPUT |
| 4 | BLK | REAR MODE VENT | INPUT |
| 5 | PUR | REAR AIR MIX POTENTIAL | INPUT |
| 6 | LT BLU | REAR EVAPORATOR TEMPERATURE SENSOR | OUTPUT |
| 8 | BLU | AUDIO UNIT (HVAC BUS) | INPUT/OUTPUT |
| 11 | ORN | REAR CLIMATE CONTROL PANEL (A/C BUS RX) | INPUT/OUTPUT |
| 12 | GRN | REAR CLIMATE CONTROL PANEL (A/C BUS TX) | INPUT/OUTPUT |
| 13 | RED | REAR BLOWER FEEDBACK | INPUT |
| 14 | BLU | REAR POWER TRANSISTOR CONTROL | OUTPUT |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.