2003 Acura 3.2CL V6-3.2L SOHCFACTORY OEM SERVICE PROCEDURE

Ignition Timing: Testing and Inspection

Ignition Timing Inspection

NOTE: Before beginning ignition timing inspection, make sure there are no DTC's present in the engine control module (ECM)/power control module (PCM).

1. Start the engine. Hold the engine at 3,000 rpm with no load (in Neutral) until the radiator fan comes on, then let it idle.
2. Check the idle speed, and adjust it if necessary.
3. Connect the PGM tester to the data link connector (16P), and follow the tester's prompts in the "SCS" menu (see the Honda PGM Tester Operator's Manual).

Factory service manual diagram



4. Connect the timing light to the No. 1 ignition coil wire.

Factory service manual diagram



5. Point the light toward the pointer (A) on the timing belt cover. Check the ignition timing under no load conditions: headlights, blower fan, rear window defogger, and air conditioner are not operating. If the ignition timing differs from the specification below, replace the ECM/PCM.

Ignition Timing:
M/T: 10 ° ± 2 ° BTDC (RED mark (B)) at idle in Neutral
A/T: 10 ° ± 2 ° BTDC (RED mark (B)) at idle in [P] or [N]

6. Disconnect the PGM tester and the timing light.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.