2003 Acura 1.7EL StandardFACTORY OEM SERVICE PROCEDURE
Float Test
- Make sure the fuel tank is less than half full.
- Remove the fuel fill cap to relieve fuel tank pressure, then reinstall the cap.
- Disconnect the fuel tank vapor recirculation tube (A), and connect a vacuum pump to the vapor recirculation tube.
- Plug the pipe (B).
- Apply vacuum to the fuel tank vapor recirculation tube.
- If the vacuum holds, replace the fuel tank vapor control valve (see Fuel Tank Vapor Control Valve ReplacementΒ ).
- If the vacuum does not hold, the float is OK. Perform the valve test.