2001 Acura 1.7EL StandardFACTORY OEM SERVICE PROCEDURE

Master Switch Input Test

NOTE: The power window control unit is built into the power window master switch, and it only controls the driver's window operations.
  1. Remove the door grip cover (see FRONT DOOR PANEL REMOVAL/INSTALLATION ).
  2. Disconnect the 20P connector (A) from the master switch (B).
    Fig 1: Disconnecting Connector From Master Switch
    G01960768
  3. Inspect the connector and socket terminals to be sure they are all making good contact.
    • If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
    • If the terminals look OK, make the following input tests at the connector.
      • If a test indicates a problem, find and correct the cause, then recheck the system.
      • If all the input tests prove OK, the power window master switch must be faulty; replace it.
    Fig 2: Master Switch Specifications Table (1 Of 2)
    G01960769
  4. Reconnect the connector to the power window master switch.
    Fig 3: Master Switch Specifications Table (2 Of 2)
    G01960770
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.