2001 Acura 1.7EL AutomaticFACTORY OEM SERVICE PROCEDURE

Valve Test

  1. Make sure the fuel tank is less than half full.
  2. Remove the fuel fill cap.
  3. Disconnect the fuel tank vapor signal tube (A).
    Fig 1: Disconnecting Fuel Tank Vapor Signal Tube
    G01954983
  4. Disconnect the vacuum hoses (A) from the EVAP canister (B), then plug the ports with plugs (C).
    Fig 2: Disconnecting Vacuum Hoses From EVAP Canister
    G01954984
  5. Disconnect the vacuum hose (D) from the EVAP canister vent shut valve (E), and connect a vacuum pump to the vacuum hose.
  6. Pump the vacuum pump 80 times.
    • If the vacuum holds, go to step 7.
    • If the vacuum does not hold, go to step Β 10.
  7. Connect a second vacuum pump to the fuel tank vapor signal tube (A).
    Fig 3: Connecting Second Vacuum Pump To Fuel Tank Vapor Signal Tube
    G01954985
  8. Apply vacuum (1 pump) to the fuel tank vapor signal tube (A), then check the vacuum on the pump in step Β 5.
  9. Fill the gas tank with fuel, then check for fuel in the EVAP two way valve (A), and fuel tank vapor recirculation hose (B).
    NOTE: At either location, tiny droplets of fuel are normal.
    • If fuel runs out of the hoses at either location, replace the fuel tank vapor control valve.
    • If the fuel does not run out of the hoses at either location, the fuel tank vapor system function is normal.
    Fig 4: Checking Fuel In EVAP Two Way Valve & Fuel Tank Vapor Recirculation Hose (1 Of 2)
    G01954986
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.