2000 Acura 1.6EL XS, AutomaticFACTORY OEM SERVICE PROCEDURE

Troubleshooting Procedures: Notes

  1. How To Begin Troubleshooting

    When the Malfunction Indicator Lamp (MIL) has been reported on, or there is a driveability problem, use the appropriate procedure below to diagnose and repair the problem.

    1. When the MIL has come on:
      1. Connect the Honda PGM Tester or an OBD II scan tool to the 16P Data Link Connector (DLC) located near the left kick panel.
      2. Turn the ignition switch ON (II).
      3. Honda PGM Tester: Begin troubleshooting as indicated by the tester. The DTC troubleshooting flowcharts are not needed with the tester; follow the tester's prompts.

        OBD II scan tool: Check the DTC and note it. Also check and note the freeze frame data. Refer to the DIAGNOSTIC TROUBLE CODE CHARTΒ  and begin troubleshooting.

        Fig 1: Identifying Malfunction Indicator Lamp (MIL)
        G06289447Courtesy of AMERICAN HONDA MOTOR CO., INC.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.