STANDARD SPECIFICATION

  MEASUREMENT STANDARD (NEW)
Ignition coil Rated voltage V 12
Primary winding resistance at 68°F (20°C) Ω 0.63 - 0.77
Secondary winding resistance at 68°F (20°C) kΩ 12.8 - 19.2
Ignition wire Resistance at 68°F (20°C) kΩ 25 max.
Spark plug Type See Engine Electrical 
Gap 1.0 - 1.1 (0.0430-00004 )
Ignition timing At idle
°BTDC (Red)
12° ± 2°
Alternator belt(1) Deflection with 98 N (10 kgf, 22 lbf) between pulleys 8.0 - 10.5 (0.31 - 0.41) with used belt
6.0 - 8.5 (0.24 - 0.33) with new belt
Belt tension N (kgf, lbf) 340 - 490 (35 - 50, 77 - 110) with used belt
Measured with belt tension gauge 540 - 740 (55 - 75, 121 - 165) with new belt
    STANDARD (NEW)  SERVICE LIMIT 
Alternator (MITSUBISHI) Output 12 Vat hot A 75  
Coil resistance (rotor) at 68°F (20°C) kΩ 3.4 - 3.8 --
Slip ring O.D. 22.7 (0.89) 22.2 (0.87)
Brush length 19.0 (0.75) 5.0 (0.20)
Brush spring tension g (oz) 300 - 450 (10.6 - 15.9) --
Starter motor (MITSUBA 1.0 kW 1.2 kW) Type Gear reduction  
Commutator mica depth 0.4-0.5 (0.016-0.020) 0.15(0.006)
Commutator runout 0 - 0.02 (0 - 0.0008) 0.05 (0.002)
Commutator O.D. 28.0 - 28.1 (1.102 - 1.106) 27.5 (1.083)
Brush length 15.8 - 16.2 (0.62 - 0.64) 11.0 (0.43)
Brush spring tension (new) 15.7 - 17.7 --
N (kgf, lbf) (1.60 - 1.80, 3.5-4.0)  
(1) When using a new belt, adjust deflection or tension to new values. Run the engine for 5 minutes then turn it off.

Readjust deflection or tension to used belt values.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.