1999 Acura 2.3CL AutomaticFACTORY OEM SERVICE PROCEDURE

Cranking Test

  1. Connect starter system tester to battery and perform starter cranking test. If starter tester is not available, connect a voltmeter and ammeter to battery. See Fig 1 . Disconnect fuse No. 33 (15 or 20-amp) from underhood fuse/relay box.
  2. Use remote starter switch to crank engine. Check cranking voltage and current draw. Ensure voltage is at least 8.5 volts. Current draw should be less than 350 amps on 2.3CL, or 380 amps on 3.0CL. Cranking speed should be greater than 100 RPM. If cranking speed is less than 100 RPM, check for loose battery or starter terminals, worn starter brushes, open commutator segments, dirty or damaged helical spline, or defective drive gear or drive gear overrunning clutch.
Fig 1: Connecting Voltmeter & Ammeter For Cranking Test
G97A11361Courtesy of AMERICAN HONDA MOTOR CO., INC.
Chapter Navigation
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.