1996 Acura 3.5RLFACTORY OEM SERVICE PROCEDURE

Fan Control Module/Unit

If fan does not operate, check for open or short circuits in wiring between components and fan control module or fan control unit. See FAN CONTROL UNIT TERMINALS table. Also see WIRING DIAGRAMSΒ . If all wiring and other components are okay, replace fan control unit.

FAN CONTROL UNIT TERMINALS

Terminal No. (1) Wire Color Circuit
1 Green/Red A/C Pressure Sw.
2 Not Used - -
3 Black Ground
4 Red/White A/C Pressure Sw.
5 Lt. Green/Black Radiator Fan Relay (-)
6 Green/Black Fan Control Sensor (-)
7 Black/Yellow Power Supply (Ign. On)
8 Pink PCM
10 Blue/Orange Condenser Fan Relay (-)
11 Not Used - -
12 Blue/Green Fan Control Sensor (+)
(1) See WIRING DIAGRAMSΒ .