1995 Acura Legend GS, AutomaticFACTORY OEM SERVICE PROCEDURE

Fail-Safe Relay

  1. Relay is located on underhood relay panel on left side, toward front. Unplug relay from socket. Using fused jumper wires, apply battery voltage between coil terminals No. 1 and 3.
  2. Continuity should exist between terminals No. 2 and 4 with voltage applied to relay coil. See Fig 1 . No continuity should exist between terminals No. 1 and 4 with no battery voltage. Replace relay if continuity is not as specified.
Fig 1: Identifying Fail-Safe Relay Terminals
G94A47423Courtesy of AMERICAN HONDA MOTOR CO., INC.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.