1995 Acura Integra GS-R, 2D CoupeFACTORY OEM SERVICE PROCEDURE

Engine Controls - Sensor Operating Range Charts: Introduction

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.

NOTE: Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
ENGINE COOLANT TEMPERATURE (ECT) SENSOR RESISTANCE

Temperature - Β°F (Β°C) (1) Ohms
-4 (-20) 15,000-18,000
68 (20) 1000-4000
176 (80) 200-400
248 (120) 50-150
(1) Measure resistance across sensor terminals.
IGNITION SENSOR RESISTANCE

Application ECM Terminals Ohms
CRANK B15 & B16 350-700
CYL B11 & B12 350-700
TDC B13 & B14 350-700
INTAKE AIR TEMPERATURE (IAT) SENSOR RESISTANCE (1)

Temperature - Β°F (Β°C) Ohms
-4 (-20) 15,000-18,000
68 (20) 2000-4000
176 (80) 300-400
(1) Measure resistance between sensor terminals.
MAP SENSOR VOLTAGE (1)

Vacuum Applied (In. Hg) Volts
0 2.8-3.0
5 2.3-2.5
10 1.8-2.0
15 1.3-1.5
20 .8-1.0
25 .3-.5
(1) Measure voltage between ECU terminals C11 (positive) and C12 (negative).
OXYGEN SENSOR VOLTAGE (1)

Condition Volts
Lean .1
Rich .9
(1) Measure voltage between ground and O2 sensor terminal using a high-impedance DVOM.
THROTTLE POSITION (TP) SENSOR VOLTAGE (1)

Position Approximate Volts
Fully Closed 0.1-0.5
Fully Open 4.5-4.8
(1) Measure resistance between terminals D11 (positive) and D22 (negative). Voltage should increase smoothly as throttle is opened.
VEHICLE SPEED SENSOR (VSS) VOLTAGE (1)

Model Approximate Volts
Integra (2)
(1) Measure voltage between terminals B10 (positive) and A26 (negative).
(2) Rotate left front wheel slowly. Voltage should pulse between zero and 10 volts.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.