Code 10: Air Temperature (Ta) Sensor

  1. Turn ignition off. Remove BACK-UP fuse (10-amp) from underhood fuse/relay box for 10 seconds to reset ECM. Check ECM for fault codes. If Code 10 is not present, problem is intermittent. Check for poor connections at ECM connector, air temperature sensor and wiring harness. Test drive vehicle and retest.
  2. If Code 10 is present, turn ignition off. Disconnect 2-pin connector from sensor connector. Using an ohmmeter, measure resistance at sensor terminals. If resistance is not 400-4000 ohms, replace air temperature sensor. If resistance is 400-4000 ohms, turn ignition on. Measure voltage between White/Yellow wire terminal and body ground.
  3. If voltage is not about 5 volts, go to next step. If voltage is about 5 volts, measure voltage between White/Yellow (+) and Green/White (-) wire terminals at sensor. If voltage is not about 5 volts, repair open in Green/White wire between ECM connector terminal D22 and air temperature sensor. If voltage is about 5 volts, replace ECM and retest.
  4. Turn ignition off. Connect ECM Test Harness (07LAJ-PT3010A ) connector "D" to ECM, leaving wiring harness disconnected. See Figure . Turn ignition on. Measure voltage between test terminals D15 (+) and D22 (-). If voltage is about 5 volts, repair open or short in White/Yellow wire between ECM connector terminal D15 and air temperature sensor. If voltage is not about 5 volts, replace ECM and retest.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.