Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1994 Acura Integra GS-R, 4D SedanFACTORY OEM SERVICE PROCEDURE
Code 1-4, Pressure Switch
- Bleed high pressure fluid from modulator. See RELIEVING SYSTEM PRESSURE. Disconnect modulator 14-pin connector. Check continuity between modulator connector Yellow wire and Black wire terminals. If continuity does not exist, go to next step. If continuity exists, visually inspect modulator wire harness. If wire harness is okay, replace modulator.
- Disconnect control unit 26-pin connector. Check continuity between Yellow wire terminal of control unit connector and ground. If continuity does not exist, go to next step. If continuity exists, Yellow wire between control unit and modulator is shorted to ground.
- Reconnect control unit 26-pin connector. Turn ignition on. Measure voltage between control unit Yellow wire terminal and ground. If battery voltage is present, pressure switch signal is okay. If battery voltage is not present, check for loose control unit connectors. If connectors are okay, install known-good control unit and retest.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.