1993 Acura Integra GS-RFACTORY OEM SERVICE PROCEDURE

Pump Pressure Check

  1. Check fluid level and belt tension. Adjust as necessary. Disconnect outlet hose from pump. Install Pump Joint Adapter (07GAK-SE00110 ) onto pump outlet fitting. See Fig 1 .
  2. Install Hose Joint Adapter (07GAK-SE00120 ) onto outlet hose. Install Pressure Gauge Set (07406-0010000 ) between pump and hose joint adapters. Fully open shutoff and pressure control valves.
  3. Start and idle engine. Turn steering wheel lock to lock several times to warm fluid. Completely close shutoff valve.
  4. Gradually close pressure control valve until pressure gauge needle stabilizes. Read pressure. Immediately open shutoff valve. Pump pressure should be at least 1140 psi (80 kg/cm2 ). Repair or replace pump if pressure is not within specification.
CAUTION: To prevent damage to pump, DO NOT keep shutoff valve closed for longer than 5 seconds.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.