1993 Acura Integra GS-RFACTORY OEM SERVICE PROCEDURE

Engine Controls - Sensor Operating Range Charts: Introduction

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.

NOTE: Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum10-megohm input impedance.
COOLANT TEMPERATURE (TW) SENSOR RESISTANCE (1)

Temperature - Β°F (Β°C) Ohms
-4 (-20) 15,000-18,000
68 (20) 2000-4000
176 (80)
Integra & Vigor 200-400
Legend 300-400
(1) Measure resistance across sensor terminals.
DISTRIBUTOR SENSOR RESISTANCE (1)

Application Ohms
Integra
CRANK Sensor 350-700
CYL Sensor 350-700
TDC Sensor 350-700
Legend
CRANK Sensor 600-950
CYL Sensor 600-950
Vigor
CRANK Sensor 650-850
CYL Sensor 650-850
TDC Sensor 650-850
(1) See appropriate I -SYSTEM/COMPONENT TESTS article in this section to identify sensor terminals.
EGR POSITION SENSOR VOLTAGE (1)

Position Approximate Volts
Fully Closed 1.0
Fully Open 4.5
(1) On Integra, measure voltage between terminals C8 (positive) and C12 (negative). On Legend and Vigor, measure voltage between terminals D12 (positive) and D22 (negative). Voltage should increase smoothly as vacuum is applied.
INTAKE AIR TEMPERATURE SENSOR RESISTANCE (1)

Temperature - Β°F (Β°C) Ohms
-4 (-20) 15,000-18,000
68 (20) 2000-4000
176 (80)
Integra & Vigor 200-400
Legend 300-400
(1) Measure resistance across sensor terminals.
MAP SENSOR VOLTAGE (1)

Vacuum Applied (In. Hg) Volts
0 2.8-3.0
5 2.3-2.5
10 1.8-2.0
15 1.3-1.5
20 .8-1.0
25 .3-.5
(1) On Integra, measure voltage between ECU terminals C11 (positive) and C12 (negative). On Legend and Vigor, measure voltage between ECU terminals D17 (positive) and D21 (negative).
OXYGEN SENSOR VOLTAGE (1)

Condition Volts
Lean .1
Rich .9
(1) Measure voltage between ground and O2 sensor terminal using a high-impedance DVOM.
THROTTLE POSITION SENSOR VOLTAGE (1)

Position Approximate Volts
Fully Closed 0.1-0.5
Fully Open 4.5-4.8
(1) On Integra, measure resistance between terminals C7 (positive) and C12 (negative). On Legend, measure resistance between terminals D11 (positive) and D22 (negative). Voltage should increase smoothly as throttle is opened.
VEHICLE SPEED SENSOR VOLTAGE (1)

Model Approximate Volts
All Models (2)
(1) On Integra and Vigor, measure voltage between terminals B10 (positive) and A26 (negative). On Legend, measure voltage between terminals C2 (positive) and D21 or D22 (negative).
(2) Rotate left front wheel slowly. Voltage should pulse between zero and 5 volts.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.