1993 Acura Integra GS-RFACTORY OEM SERVICE PROCEDURE
Engine Controls - Adjustments: Integra
- Cylinder head temperature must be less than 100Β°F (38Β°C). Remove valve cover, timing belt covers and distributor cap.
- Align pointer on timing belt lower cover with TDC (White mark). UP marks on both camshaft sprockets should be at top of cam gears. Distributor rotor should point to No. 1 spark plug wire on cap. Adjust valves on cylinder No. 1.
- Rotate crankshaft counterclockwise 180 degrees to bring No. 3 piston to TDC on compression stroke. Adjust valves on cylinder No. 3.
- Rotate crankshaft counterclockwise 180 degrees to bring No. 4 piston to TDC on compression stroke. Adjust valves on cylinder No. 4.
- Rotate crankshaft counterclockwise 180 degrees to bring No. 2 piston to TDC on compression stroke. Adjust valves on cylinder No. 2.VALVE CLEARANCE ADJUSTMENT - INTEGRA
Application (1) In. (mm) 1.7L Intake .0059-.0075 (.150-.190) Exhaust .0067-.0083 (.170-.210) 1.8L Intake .0031-.0047 (.080-.120) Exhaust .0063-.0079 (.160-.200) (1) Adjust valves when engine is cold.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.