1992 Acura Vigor LS, StandardFACTORY OEM SERVICE PROCEDURE
Code 1: O2 Sensor
- Turn ignition off. Remove BACK UP fuse at battery positive terminal for 10 seconds to reset ECU. Start and warm engine to normal operating temperature.
- Road test vehicle. With transmission in second gear, accelerate at wide open throttle for at least 5 seconds, and then decelerate with throttle fully closed for at least 5 seconds.
- Check ECU for fault codes. See RETRIEVING CODESΒ . If Code 1 is not present, problem is intermittent. Check for poor connections at ECU connector and O2 sensor. If Code 1 is present, go to CODE 43: FUEL SUPPLY SYSTEMΒ .
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.