1992 Acura Vigor LS, StandardFACTORY OEM SERVICE PROCEDURE

Ignition Coil Test (Vigor)

Turn ignition off. Disconnect ignition coil connector. See Fig 1 . Using an ohmmeter, check resistance between indicated terminals. See IGNITION COIL RESISTANCE (VIGOR)Β  table. Replace coil if readings are not within specifications.

IGNITION COIL RESISTANCE (VIGOR)

Application Ohms @ 68Β°F (20Β°C)
Terminals A & D (Primary) .3-.5
Terminals B & D 2090-2310
Terminal A & Secondary Terminal 10,800-16,200
Fig 1: Testing Ignition Coil (Vigor)
G92E26199Courtesy of AMERICAN HONDA MOTOR CO., INC.