1992 Acura Integra GS-RFACTORY OEM SERVICE PROCEDURE

Pump Pressure Check

  1. Check fluid level and belt tension. Adjust as necessary. Disconnect outlet hose from pump. On Integra, install Pump Joint Adapter (07GAK-SE00110 ) on pump outlet. On Legend, install Pump Joint Adapter (07GAD-SE00112 ) on pump outlet.
  2. On all models, install Hose Joint Adapter (07GAK-SE00120 ) to outlet hose. Install Pressure Gauge Set (07406-0010000 ) between pump and hose joint adapters. Fully open shutoff and pressure control valves.
  3. Start engine and let idle. Turn steering wheel lock-to-lock several times until fluid is at operating temperature. Completely close shutoff valve.
    CAUTION: DO NOT keep shutoff valve closed for more than 5 seconds, or pump could be damaged.
  4. Gradually close pressure control valve until pressure gauge needle stabilizes. Read pressure. Fully open shutoff valve. Pump pressure should be at least 1138-1280 psi (80-93 kg/cm2 ). Repair or replace pump if pressure is not within specification.
Chapter Navigation
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.