Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1992 Acura Integra GS-RFACTORY OEM SERVICE PROCEDURE
Main Switch: Integra
- Remove main switch from instrument panel. Ensure main switch is off. Using a DVOM, check for continuity between main switch terminals "B" and "C" and terminals "D" and "E". See Fig 1 . Continuity should be present. If continuity is present, go to next step. If continuity is not present, replace defective bulb inside main switch. Locate bulb on left side of main switch and rotate bulb 1/2 turn to remove from switch. After replacing bulb inside main switch, if main switch continuity readings are not as specified, replace malfunctioning main switch.
- Ensure main switch is on. Using a DVOM, check for continuity between main switch terminals "A" and "B", "B" and "C", and "D" and "E". See Fig 1 . Continuity should be present. If continuity is present, main switch is okay. If continuity is not present, between main switch terminals "A" and "B", replace malfunctioning main switch. If continuity is not present between main switch terminals "B" and "C" and terminals "D" and "E", go to next step.
- Replace defective bulb inside main switch. Locate bulb on left side of main switch and rotate bulb 1/2 turn to remove from switch. After replacing bulb inside main switch, if main switch continuity readings are not as specified, replace malfunctioning main switch.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.
