1988 Acura Integra LS, 2D Hatchback, AutomaticFACTORY OEM SERVICE PROCEDURE
Code 20 - Electrical Load Detector
- Turn ignition off and remove hazard at battery positive terminal for 10 seconds to reset ECU. Start engine and observe Check Engine light. If light is off, problem is intermittent. Test drive and check again.
- If light is on, turn ignition off. Open lid of main fuse panel in engine compartment. Disconnect 3-wire electrical load detector. Turn ignition on. Measure voltage between Black/Yellow (pos.) and Black (neg.) wire terminals of harness. If battery voltage is present, go to step 4).
- Measure voltage between Black/Yellow wire and ground. If battery voltage is now present, repair open in Black wire between connector and ground. If battery voltage is not present, repair open Black/Yellow wire between No. 4 fuse and connector.
- Turn ignition off. Connect system checker harness between ECU and ECU connector. Disconnect "B" connector from ECU only, not main harness. Connect Green/Red terminal of connector to ground. Check for continuity between ECU terminal B19 and ground. If continuity does not exist, repair open Green/Red wire between ECU connector terminal B19 and load detector connector.
- Reconnect "B" connector to ECU. Turn ignition on. Measure voltage between Green/Red (pos.) and Black (neg.) terminals of the load detector harness. If 4.5-5 volts is present, go to step 7). If 4.5-5 volts isn't present, disconnect "B" connector from main wiring harness, not the ECU. Measure voltage between terminals B19 (pos.) and A18 (neg.)
- If voltage is now 4.5-5 volts, repair short in Green/Red wire between ECU terminal B19 and load detector connector. If voltage is not 4.5-5 volts, substitute a known good ECU. If correct voltage is now available, replace original ECU.
- Reconnect load detector connector. Measure voltage between terminals B19 (pos.) and A18 (neg.) under the following conditions.
- Headlight switch in first position - Voltage should be 2.5-3.5 volts.
- Headlight switch in second position - Voltage should be 1.5-2.5 volts.
- If voltage is not as noted replace faulty electrical load detector. If voltage responds as indicated, substitute a known good ECU. If condition is rectified, replace original ECU.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.