1988 Acura Integra LS, 2D Hatchback, AutomaticFACTORY OEM SERVICE PROCEDURE

Code 15 - Ignition Output Signal

  1. Turn ignition off and remove hazard fuse at battery positive terminal for 10 seconds to reset ECU. Start engine and observe Check Engine light. If light is off, problem is intermittent. Test drive and check again.
  2. If light is on, turn ignition off. Disconnect 2-wire connector at distributor. Turn ignition on. Measure voltage between ground and Black/Yellow wire terminal on ignition side of harness. If battery voltage is not present, repair open Black/Yellow wire between connector and ignition switch.
  3. If battery voltage is present, turn ignition off. Reconnect 2-wire connector. Connect system checker harness between ECU and ECU connector. Turn ignition on. Individually, measure voltage between terminal A18 (neg.) and terminals B15 and B17. If battery voltage is present, go to next step. If battery voltage is not present, repair open in wires between distributor and ECU terminals B15 or B17 or replace faulty Ignitor unit.
  4. Substitute a known good ECU. If condition is rectified, replace original ECU.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.