Lexus 2020 UX 250h Base · Repair and Diagnosis (Single Page)

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A0015: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A0814: DC/DC Converter Status Circuit Short to Ground or Open [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A1114: DC/DC Converter Enable Circuit Short to Ground or Open [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A1B-1F: Generator Control Module Circuit Intermittent [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A1C-49: Drive Motor "B" Control Module Internal Electronic Failure [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F1F: Drive Motor "A" Position Sensor Circuit Intermittent [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B1F: Generator Position Sensor Circuit Intermittent [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B22: Generator Position Sensor Signal Amplitude > Maximum [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A6014: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A601C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A601F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A6312: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A6314: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A631C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A631F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A78-72: Drive Motor "A" Inverter Actuator Stuck Open [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A78-73: Drive Motor "A" Inverter Actuator Stuck Closed [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D19: Drive Motor "A" Inverter Circuit Current Above Threshold [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A7A-72: Generator Inverter Actuator Stuck Open [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A7A-73: Generator Inverter Actuator Stuck Closed [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (1 Of 3) / Motor Generator Control System / DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F19: Generator Inverter Circuit Current Above Threshold [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (2 Of 3) / Motor Generator Control System / DTC P0A90-00: Drive Motor "A" Performance [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (2 Of 3) / Motor Generator Control System / DTC P0A92-00: Hybrid Generator Performance [10/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System (Diagnostic Codes) (2 Of 3) / Motor Generator Control System / DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D3319: DC/DC Converter Circuit Current Above Threshold [10/2018 - ]