Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A00-15: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range [09/2016 - 12/2018]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range [12/2018 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A08-14: DC/DC Converter Status Circuit Short to Ground or Open [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A11-14: DC/DC Converter Enable Circuit Short to Ground or Open [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A1B-1F: Generator Control Module Circuit Intermittent [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F-1F: Drive Motor "A" Position Sensor Circuit Intermittent [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F-22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B-1F: Generator Position Sensor Circuit Intermittent [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A60-12: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A78-73: Drive Motor "A" Inverter Actuator Stuck Closed [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D-19: Drive Motor "A" Inverter Circuit Current Above Threshold [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A7A-73: Generator Inverter Actuator Stuck Closed [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F-19: Generator Inverter Circuit Current Above Threshold [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A90-00: Drive Motor "A" Performance [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (2 Of 3) / Motor Generator Control System / DTC P0A92-00: Hybrid Generator Performance [09/2016 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Motor Generator Control System - Diagnostic Codes (3 Of 3) / Motor Generator Control System / DTC P0E57-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold [09/2016 - ]