Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (2 Of 5) / Hybrid Battery System / DTC P0ABF-2A: Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range [01/2017 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (3 Of 5) / Hybrid Battery System / DTC P0B13-62: Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (3 Of 5) / Hybrid Battery System / DTC P0B13-62: Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (3 Of 5) / Hybrid Battery System / DTC P0C30-00: Hybrid/EV Battery State of Charge High [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (3 Of 5) / Hybrid Battery System / DTC P0C30-00: Hybrid/EV Battery State of Charge High [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (3 Of 5) / Hybrid Battery System / DTC P0E2D-00: Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance [01/2017 - 09/2018]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (3 Of 5) / Hybrid Battery System / DTC P0E2D-00: Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance [09/2018 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (3 Of 5) / Hybrid Battery System / DTC P0E2D-00: Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (3 Of 5) / Hybrid Battery System / DTC P1A00-1C: Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range; DTC P301A-1C: Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A00-1C: Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range; DTC P301A-1C: Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A60-17: Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold; DTC P31AA-17: Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A60-17: Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold; DTC P31AA-17: Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A61-16: Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold; DTC P31AB-16: Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A61-16: Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold; DTC P31AB-16: Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A80-00: Hybrid/EV Battery Stack 1 Delta SOC High; DTC P1A85-00: Hybrid/EV Battery Stack 2 Delta SOC High [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A80-00: Hybrid/EV Battery Stack 1 Delta SOC High; DTC P1A85-00: Hybrid/EV Battery Stack 2 Delta SOC High [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A81-00: Hybrid/EV Battery Stack 1 Delta SOC High (Extreme); DTC P1A86-00: Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1A81-00: Hybrid/EV Battery Stack 1 Delta SOC High (Extreme); DTC P1A86-00: Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1AFC-00: System Voltage (AM) Circuit Voltage Below Threshold [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1AFC-00: System Voltage (AM) Circuit Voltage Below Threshold [05/2023 - ]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1AFD-00: Flying Capacitor Circuit Voltage Out of Range [01/2017 - 05/2023]

Hybrid/Electric Powertrain / Testing and Diagnosis / Hybrid Battery System - Diagnostic Codes (4 Of 5) / Hybrid Battery System / DTC P1AFD-00: Flying Capacitor Circuit Voltage Out of Range [05/2023 - ]